INSTALLATION AND OPERATION
| At the end of a cable hangs a bell shaped cone
containing a micro switch which operates when the cone is tilted some 25° in any
direction from its normal vertical position. |

The unit must be installed a minimum of 250 mm from the
silo wall and a minimum of 300 mm from the centre opening. 40 mm of cable is required from the end of the protective conduit to the cone. The same
requirements hold true for the side mounted switch. When the silo is filled to the predetermined capacity the switch is activated by the
rising level of the item being stored.
Examples of Density differences causing different degrees of tilt in different
items:

| - gravel about 55° |
|
|
| - wheat about 45° |
|
|
| - barley about 40° |
|
|
| - oats about 38° |
|
|
| - grain about 40° |
|
|
|
|
|
| Technical
Information: |
|
|
| Voltage |
250 V AC |
|
| Current |
1A AC1 |
|
| Weight |
160 g |
|
| Operating temperature |
-20°C - +60 °C |
|
| Cable dimensions |
2x1 mm2, 2 m |
|
| Tightness |
IP65 |
|
| Bell material |
ABS |
|
| Cable Insulation |
rubber |
|
|
|
|
|
Type S1, NO |
Type S2, NC |

|